Performance Differences Seen in Continuous Glucose Monitors

In head-to-head-to-head comparative effectiveness study, Navigator was most accurate CGM device

FRIDAY, Jan. 25 (HealthDay News) -- Continuous glucose monitoring (CGM) devices vary in performance characteristics, according to a comparative effectiveness study published online Dec. 28 in Diabetes Care.

Edward R. Damiano, Ph.D., from Boston University, and colleagues recruited six patients with type 1 diabetes (age 52 ± 14 years) to participate in two 51-hour closed-loop blood glucose control experiments. Subjects simultaneously wore three CGM devices -- the Navigator (Abbott Diabetes Care), the Seven Plus (DexCom), and the Guardian (Medtronic) -- to obtain CGM glucose (CGMG) measurements. Measurements were paired with corresponding venous plasma glucose (PG) measurements (GlucoScout, International Biomedical) obtained every 15 min (2,360 values).

The researchers found that the Navigator had the best overall accuracy, with an aggregate mean absolute relative difference (MARD) of all paired points (PG-CGMG measurements) of 11.8 ± 11.1 percent and an average MARD across all 12 experiments of 11.8 ± 3.8 percent. The Seven Plus had an aggregate MARD of all paired points of 16.5 ± 17.8 percent and an average MARD across all 12 experiments of 16.5 ± 6.7 percent. For the Guardian, the corresponding figures were 20.3 ± 18.0 percent and 20.2 ± 6.8 percent. Reliability, as measured by data reporting percentages, was 76 percent for the Seven Plus and close to 100 percent for the Navigator and Guardian.

"The results of this head-to-head-to-head comparative effectiveness study reveal the Navigator was the most accurate and precise of the current generation of CGM devices, followed by the Seven Plus and the Guardian," the authors write.

International Biomedical provided GlucoScout monitors and technical assistance regarding their use.

Abstract
Full Text (subscription or payment may be required)

Health News Copyright © 2013 HealthDay. All rights reserved.

Powered by

jQuery UI Accordion - Default functionality

For life-long learning and continuing professional development, come to Lippincott's NursingCenter.

Nursing Jobs Plus
Featured Jobs
Recommended CE Articles

Blunt Chest Trauma
Journal of Trauma Nursing, November/December 2014
Expires: 12/31/2016 CE:2 $21.95


The School Age Child with Congenital Heart Disease
MCN, The American Journal of Maternal/Child Nursing, January/February 2015
Expires: 2/28/2017 CE:2.5 $24.95


Understanding multiple myeloma
Nursing Made Incredibly Easy!, January/February 2015
Expires: 2/28/2017 CE:2 $21.95


More CE Articles

Subscribe to Recommended CE

Recommended Nursing Articles

Comprehensive Care: Looking Beyond the Presenting Problem
Journal of Christian Nursing, January/March 2015
Free access will expire on March 2, 2015.


Pain and Alzheimer dementia: A largely unrecognized problem
Nursing Made Incredibly Easy!, January/February 2015
Free access will expire on February 16, 2015.


Glycemic control in hospitalized patients
Nursing2015 Critical Care, January 2015
Free access will expire on February 16, 2015.


More Recommended Articles

Subscribe to Recommended Articles

Evidence Based Practice Skin Care Network NursingCenter Quick Links What’s Trending Events