Keywords

hemodialysis, respiratory function tests, breathing exercise, incentive spirometry, six-minute walk test

 

Authors

  1. ARAZI, Tajmohammad

ABSTRACT

Background: Pulmonary disorders and poor functional capacity are common complications in patients under hemodialysis. Although breathing exercise is frequently prescribed to improve respiratory function, its efficacy in this patient community is not well established.

 

Purpose: Our study was designed to determine the effectiveness of a breathing exercise on respiratory function and 6-minute walk (6MW) distance in patients under hemodialysis.

 

Methods: A randomized controlled trial approach was used. The sample consisted of 52 patients under hemodialysis from a university teaching hospital in Iran. The experimental group (n = 26) received the breathing exercise program and was encouraged to perform incentive spirometry for 2 months. The control group (n = 26) received only routine hospital care. The respiratory function test and 6MW test were performed at baseline and at 2 months after the intervention (posttest).

 

Results: The two groups were homogeneous in terms of respiratory function parameters, 6MW distance, and demographic characteristics at baseline. Forced expiratory volume in 1 second and forced vital capacity were significantly better in the experimental group compared with the control group at 2 months after intervention. No significant difference was found in 6MW distance between the groups at the 2-month posttest.

 

Conclusions/Implications for Practice: The 2-month breathing exercise effectively improved pulmonary function parameters (forced vital capacity, forced expiratory volume in 1 second) in patients under hemodialysis but did not affect 6MW distance. Hemodialysis nurses should strengthen their clinical health education and apply breathing exercise programs to reduce the pulmonary complications experienced by patients under hemodialysis.

 

Article Content

Introduction

Chronic kidney disease (CKD), an increasing concern worldwide, is characterized by irreversible destruction of nephrons (De Nicola & Zoccali, 2016; Lin et al., 2013). CKD is a complicated and progressive disorder that affects most important organ systems, including the cardiovascular, musculoskeletal, metabolic, and respiratory systems (Webster et al., 2017). Pulmonary complications are important and prevalent disorders in patients with CKD, with prominent complications including pleural effusion, pulmonary edema, pulmonary hypertension, and acute respiratory distress syndrome (Hsieh et al., 2016; Palamidas et al., 2014). Hemodialysis is the most common method used to treat kidney failure in patients with CKD (de Almeida et al., 2019). Although hemodialysis reduces some CKD complications, impaired pulmonary function is a prevalent complication that leads to severe problems in patients under hemodialysis (Cho et al., 2018; Unal et al., 2010). Pulmonary disorders in these patients may be the result of fluid overload, high blood pressure, permeability of the capillaries, or circulating uremic toxins (Y[latin dotless i]lmaz et al., 2016). Respiratory disorders are common complications among Iranian patients under hemodialysis, and a high prevalence of pulmonary hypertension has been shown in this population (Mousavi et al., 2008). Breathing exercises are frequently a convenient and simple strategy to improve lung efficiency, and the incentive spirometer (IS) is a device that is widely used in these exercises (Alaparthi et al., 2016). IS works to expand the user's lungs by allowing deeper breathing and is used to help patients improve lung functioning (Restrepo et al., 2011). Although medical evidence indicates that IS device may be useful in preventing pulmonary complications, the degree of benefit in different populations such as patients under hemodialysis, patients undergoing coronary artery bypass graft surgery, and patients with lung cancer is uncertain, and there are significant discrepancies among physicians in terms of the medical efficacy of using IS (Haeffener et al., 2008; Liu et al., 2019; Silva et al., 2011). Moreover, patients with CKD experience reduced physical performance, and studies have shown that patients under hemodialysis experience significantly lower physical functional capacity, as evaluated by the 6-minute walk (6MW) test, than their healthy adult peers (Bucar Pajek et al., 2016). Pulmonary complication is one of the reasons that patients under hemodialysis experience poor functional exercise capacities (Smith & Burton, 2012). The 6MW test is a well-tolerated submaximal exercise test that aids in the assessment of functional capacity and provides valuable information about physical performance and response to therapy in cases of chronic cardiopulmonary disease such as chronic pulmonary hypertension (Ghofraniha et al., 2015). Therefore, this study was designed to determine the effectiveness of a breathing exercise on respiratory function and 6MW distance in patients under hemodialysis.

 

Methods

Design

This study used a randomized, nonblinded controlled trial approach with two groups (experimental and control).

 

Setting and Participant

This study was conducted at Shahid Hasheminejad Kidney Center, which is the national referral center for urology and nephrology in Iran. The participants were patients undergoing hemodialysis in the dialysis ward. Data were collected from November 2018 to March 2019. Study inclusion criteria included (a) >=18 years old; (b) forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1) values at least 15% below the normal ranges, based on age and height; (c) having normal thoracic and vertebral column and legs; (d) being able to perform the breathing exercise and the 6MW test; (e) currently receiving hemodialysis three times a week; and (f) under hemodialysis for at least 6 months. Otherwise eligible patients were excluded from this study if they had an acute respiratory disease or respiratory infections during the study period or if they were unable or unwilling to participate.

 

Sampling

This study followed a similar study (Haeffener et al., 2008) in targeting 99% power and 95% confidence interval and aiming to find a minimum 4% difference in FVC and FEV1 among the two groups. Thus, a minimum of 17 patients was required in each group. Fifty-two patients (26 per group) participated in the study, accounting for a possible sample loss up to 50%.

 

One hundred eighty patients visited the target hospital for hemodialysis three times per week. Of these, 87 visited the hospital on even-numbered days of the week, and 93 visited the hospital on odd-numbered days of the week. Cluster randomization was initially advocated to minimize treatment contamination between the two groups. Days of the week were randomly assigned to the experimental (even-numbered days) and control (odd-numbered days) arms by flipping a coin. Subsequently, 87 patients in the even-day pool and 93 patients in the odd-day pool were assessed for eligibility. Thirty-four and 32 patients, respectively, in the two pools failed to meet the inclusion criteria and were excluded from the randomization list. Finally, 26 eligible patients in each cluster (n = 53 in the experimental arm and n = 61 in the control arm) were assigned randomly to the study by a random number generator application. All 52 patients (26 per group) completed the study program, and all completed the posttest questionnaire at 2 months after program completion (Figure 1).

  
Figure 1 - Click to enlarge in new windowFigure 1. Study Design Flowchart

Intervention

The experimental group received the breathing exercise program in addition to routine hospital care. The breathing exercise program included use of the IS device. The experimental group participants were instructed in how to use the IS and were asked to (a) "hold the IS in an upright position"; (b) "put the mouthpiece spirometer in your mouth"; (c) "after quiet expiration, inhale deeply and slowly"; (d) "hold your breath for as long as possible and then exhale normally"; and (e) "repeat each of these steps 10 times every hour after you wake up for a period of 2 months." The researcher provided each patient with one IS device and an associated pictorial educational booklet. All of the IS devices used in this study were similar and of the same brand. Compliance with the breathing exercise was assessed via telephone calls every week. All of the participants in the experimental group adhered to the breathing exercise program, and no complaints were reported by these participants regarding using the IS device. The remaining 26 patients (control group) received only routine hospital care, which included connecting the patient to the hemodialysis machine, performing weight control, and providing education on fluid imbalance, hypertension, nutritional diet, and the prevention of hemodialysis complications such as muscle cramps and peripheral edema.

 

Outcome Measures

Respiratory function parameters and 6MW distance, assessed using the FVC and FEV1 test and the 6MW test, were the primary end point measures used in this study. The respiratory function tests, including the FVC, FEV1, and 6MW tests, were performed in both groups at baseline as well as 2 months after study enrollment. One standard spirometer model (model: Flowhandy ZAN Type 3.1) was used during the study. The reliability of this spirometer was assessed using the test-retest method. To assess reliability, the respiratory function test was measured in 15 subjects twice within 5 minutes under the same conditions. The obtained correlation coefficient was 95%.

 

The 6MW test was performed in accordance with the comprehensive guidelines developed by the American Thoracic Society (ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories, 2002). All of the participants performed the 6MW test along a 30-meter-long, flat and comfortable surface in the hospital (marked with meter tacks). They were instructed to (a) wear comfortable shoes and clothes, (b) rest for 10 minutes before doing the test (during which time heart rate and blood pressure were measured and potential contraindications were assessed by the researcher), and (c) walk for 6 minutes. All necessary information was given to the participants, including walking speed, stop time, and advice regarding potential adverse feelings such as fatigue, cramps, chest pain, and dyspnea. The supervisor used standard phrases of encouragement (e.g., you are doing fine) recommended by the American Thoracic Society.

 

Data Analysis

The SPSS Version 16.0 (SPSS, Inc., Chicago, IL, USA) was used to examine the data. Descriptive statistics such as mean, standard deviation, and percentage were used to describe the baseline characteristics of the patients. Statistical analyses to identify the differences among the groups included unpaired t tests and chi-square test.

 

Ethical Approval

The ethical research committee of Tehran University of Medical Sciences reviewed and approved this study (approval number: 91-02-28-18230), and the study was registered in the Iranian Registry of Clinical Trials under Registration Code IRCT2012080522226N10. All of the participants provided informed consent and were assured that their participation was voluntary and that their data would be anonymized and kept confidential. Furthermore, the participants were informed that they could withdraw from the study at any time without any negative impact to their regular treatment.

 

Results

Experimental and control group demographic characteristics are compared in Table 1. This study found no significant differences in baseline characteristics between the groups. Most of the participants in both groups were middle-aged women. No significant intergroup differences were found in terms of gender (p = .57), age (p = .08), weight (p = .68), or time since diagnosis (p = .59).

  
Table 1 - Click to enlarge in new windowTable 1. Baseline Characteristics of the Research Sample

Respiratory function tests and 6MW distance were compared between the two groups at baseline, with results shown in Table 2. No significant intergroup difference was found at baseline in terms of FEV1 (p = .54), FVC (p = .33), and 6MW distance (p = .68). At the 2-month posttest, the experimental group earned significantly better values in terms of FEV1 (p = .02) and FVC (p = .04) than the control group. However, no significant intergroup difference was found in terms of 6MW distance at the 2-month posttest (p = .43; Table 2).

  
Table 2 - Click to enlarge in new windowTable 2. Comparison of Outcomes Between the Experimental and Control Groups at Baseline and at 2 Months After the Intervention (Posttest)

Discussion

This study investigated the efficacy of a breathing exercise on respiratory function and 6MW distance in patients under hemodialysis. Although the use of IS as a breathing exercise has increased in recent years and IS is now frequently prescribed to improve respiratory function, there is limited evidence supporting its benefits. Moreover, no clear evidence establishing the effectiveness of IS in improving respiratory function and functional capacity in patients under hemodialysis has been published (Eltorai et al., 2018).

 

In this study of patients under hemodialysis, the data analysis showed a positive effect of using IS on respiratory function test results (FVC, FEV1). These findings are congruent with the finding of a previous study that practicing a breathing exercise with IS (IS training for 2 months, three sessions per week) improved diaphragmatic excursion in patients under hemodialysis (Mansour et al., 2018). In addition, a systematic review showed that inspiratory muscle training with a load ranging from 30% to 60% of the maximal inspiratory pressure and lasting from 2 to 6 months has the potential to improve respiratory muscle strength, functional capacity, and lung function in patients with CKD (de Medeiros et al., 2017). Despite the above, some studies have recommended against adding IS to the common standard of treatment (Tyson et al., 2015). Martin et al. cited patients' nonadherence to IS protocols as an important factor behind patients failing to achieve the positive effect of IS. They mentioned that patient perspectives on the potential benefits of IS, multimedia patient education, and previous use of the device may improve the rate of correct IS usage and increase compliance during IS implementation (Martin et al., 2018). Analysis of a systematic review study (Narayanan et al., 2016) revealed an inconsistency in the evidence related to IS compliance. Therefore, comprehensive research in these areas is needed to help obtain valid inferences regarding the effectiveness of using IS.

 

Respiratory disorders are a leading cause of poor exercise capacities in patients under hemodialysis, with these patients experiencing significantly poorer exercise capacities, as evaluated using the 6MW test, than healthy adults (Bucar Pajek et al., 2016; Watanabe et al., 2016). This study was designed to investigate the effect of a breathing exercise on 6MW distance in patients under hemodialysis. Although the mean walking distance of the experimental group had improved by about 10 meters at the 2-month posttest, no significant difference was found between the two groups at the 2-month posttest. The results of this study echo the findings of Aliasgharpour and Hadiyan (2011), which showed that, although the 6MW distance of patients under hemodialysis in the intervention group increased after doing the exercise, the increase did not result in a statistically significant posttest difference between the intervention and control groups. Contrary to our results, Silva et al. (2011) found that inspiratory muscle training for 2 months significantly increased 6MW distance scores in patients under hemodialysis but no did not affect pulmonary function.

 

In addition to respiratory complications, other factors such as uremic myopathy, anemia, and malnutrition are known to affect the results of the 6MW distance test in patients under hemodialysis. The breathing exercise program did not affect these factors, which may be a reason why the participants in this study exhibited effectively improved pulmonary function parameters but no significant change in 6MW distance.

 

A review of related articles found inconsistent evidence regarding a positive effect for breathing exercises on functional capacity and endurance as measured using the 6MW test in patients. Further prospective studies should be conducted to evaluate the use of IS in this context and to compare results with respiratory physical therapeutic techniques and other respiratory devices.

 

Research Limitations

During this study, patient follow-up was conducted by telephone call only (no home visits). To remedy this limitation, this intervention should be repeated using home visits, observational follow-up, or hourly, audible reminders for IS implementation.

 

Conclusions/Implication for Practice

The findings of the study showed that the use of IS improves pulmonary function parameters (FVC, FEV1) and does not significantly change 6MW distance. An IS is a convenient and inexpensive breathing exercise device that may easily be used by patients under hemodialysis to improve their respiratory functions.

 

Hemodialysis nurses spend far more time with patients than other healthcare workers and are responsible for teaching patients about preventing and managing hemodialysis complications. Therefore, teaching breathing exercises to patients under hemodialysis as a safe way to reduce pulmonary complications may play an important role in improving pulmonary outcomes in these patients.

 

Acknowledgments

Our research was supported by the Tehran University of Medical Sciences. We would like to thank all of the respectful staff and patients of the Hashemi Nejad Hospital in Tehran who helped us in this study.

 

Author Contributions

Study conception and design: SM, MA, TA.

 

Data collection: SM, TA.

 

Data analysis and interpretation: AK, NM.

 

Drafting of the article: SM, TA, NM, AK.

 

Critical revision of the article: SM, TA, NM.

 

References

 

Alaparthi G. K., Augustine A. J., Anand R., Mahale A. (2016). Comparison of diaphragmatic breathing exercise, volume and flow incentive spirometry, on diaphragm excursion and pulmonary function in patients undergoing laparoscopic surgery: A randomized controlled trial. Minimally Invasive Surgery, 2016, Article ID 1967532. https://doi.org/10.1155/2016/1967532[Context Link]

 

Aliasgharpour M., Hadiyan Z. (2011). Assessment of a designed exercise program on physical capacity using six-minute walking test (6MWT) in hemodialysis patients. Journal of Hayat, 17(3), 59-68. (Original work published in Persian) [Context Link]

 

ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories. (2002). ATS statement: Guidelines for the six-minute walk test. American Journal of Respiratory and Critical Care Medicine, 166, 111-117. [Context Link]

 

Bucar Pajek M., Cuk I., Leskosek B., Mlinsek G., Buturovic Ponikvar J., Pajek J. (2016). Six-minute walk test in renal failure patients: Representative results, performance analysis and perceived dyspnea predictors. PLOS ONE, 11(3), Article ID e0150414. [Context Link]

 

Cho M.-K., Kim S. Y., Shim H. Y. (2018). Validity and reliability of the Korean version of the dialysis symptom index for hemodialysis patients. The Journal of Nursing Research, 26(6), 399-410. [Context Link]

 

de Almeida C. P., Ponce D., Balbi A. L. (2019). Effect of hemodialysis on respiratory mechanics in acute kidney injury patients. Hemodialysis International, 23(1), 101-105. [Context Link]

 

de Medeiros A. I. C., Fuzari H. K. B., Rattesa C., Brandao D. C., de Melo Marinho P. E. (2017). Inspiratory muscle training improves respiratory muscle strength, functional capacity and quality of life in patients with chronic kidney disease: A systematic review. Journal of Physiotherapy, 63(2), 76-83. [Context Link]

 

De Nicola L., Zoccali C. (2016). Chronic kidney disease prevalence in the general population: Heterogeneity and concerns. Nephrology, Dialysis, Transplantation, 31(3), 331-335. [Context Link]

 

Eltorai A. E. M., Szabo A. L., Antoci V. Jr., Ventetuolo C. E., Elias J. A., Daniels A. H., Hess D. R. (2018). Clinical effectiveness of incentive spirometry for the prevention of postoperative pulmonary complications. Respiratory Care, 63(3), 347-352. [Context Link]

 

Ghofraniha L., Dalir Sani Z., Vakilian F., Khajedalooyi M., Arabshahi Z. J. (2015). The six-minute walk test (6MWT) for the evaluation of pulmonary diseases. Journal of Cardio-Thoracic Medicine, 3(2), 284-287. [Context Link]

 

Haeffener M. P., Ferreira G. M., Barreto S. S. M., Arena R., Dall'Ago P. (2008). Incentive spirometry with expiratory positive airway pressure reduces pulmonary complications, improves pulmonary function and 6-minute walk distance in patients undergoing coronary artery bypass graft surgery. American Heart Journal, 156(5), 900.e1-900.e8. [Context Link]

 

Hsieh C. W., Lee C. T., Chen C. C., Hsu L. P., Hu H. H., Wu J. C. (2016). Pulmonary hypertension in patients on chronic hemodialysis and with heart failure. Hemodialysis International, 20(2), 208-217. [Context Link]

 

Lin C. C., Chen M. C., Hsieh H. F., Chang S. C. (2013). Illness representations and coping processes of Taiwanese patients with early-stage chronic kidney disease. The Journal of Nursing Research, 21(2), 120-128. [Context Link]

 

Liu C.-J., Tsai W.-C., Chu C.-C., Muo C.-H., Chung W.-S. (2019). Is incentive spirometry beneficial for patients with lung cancer receiving video-assisted thoracic surgery?BMC Pulmonary Medicine, 19(1), Article No. 121. [Context Link]

 

Mansour H. S., El-Dein H. M. E., Mohamed F. A., Ahmed T. F. (2018). Efficacy of incentive spirometer training on diaphragmatic excursion and quality of life in hemodialysis patients. The Medical Journal of Cairo University, 86, 3997-4002. [Context Link]

 

Martin T. J., Patel S. A., Tran M., Eltorai A. S., Daniels A. H., Eltorai A. E. M. (2018). Patient factors associated with successful incentive spirometry. Rhode Island Medical Journal, 101(9), 14-18. [Context Link]

 

Mousavi S. A., Mahdavi-Mazdeh M., Yahyazadeh H., Azadi M., Rahimzadeh N., Yoosefnejad H., Ataiipoor Y. (2008). Pulmonary hypertension and predisposing factors in patients receiving hemodialysis. Iranian Journal of Kidney Diseases, 2(1), 29-33. [Context Link]

 

Narayanan A. L., Hamid S. R., Supriyanto E. (2016). Evidence regarding patient compliance with incentive spirometry interventions after cardiac, thoracic and abdominal surgeries: A systematic literature review. CJRT: Canadian Journal of Respiratory Therapy, 52(1), 17-26. [Context Link]

 

Palamidas A. F., Gennimata S. A., Karakontaki F., Kaltsakas G., Papantoniou I., Koutsoukou A., Milic-Emili J., Vlahakos D. V., Koulouris N. G. (2014). Impact of hemodialysis on dyspnea and lung function in end stage kidney disease patients. BioMed Research International, 2014, Article ID 212751. [Context Link]

 

Restrepo R. D., Wettstein R., Wittnebel L., Tracy M. (2011). Incentive spirometry: 2011. Respiratory Care, 56(10), 1600-1604. [Context Link]

 

Silva V. G., Amaral C., Monteiro M. B., Nascimento D. M., Boschetti J. R. (2011). Effects of inspiratory muscle training in hemodialysis patients. Brazilian Journal of Nephrology (Jornal Brasileiro de Nefrologia), 33(1), 62-68. [Context Link]

 

Smith A. C., Burton J. O. (2012). Exercise in kidney disease and diabetes: Time for action. Journal of Renal Care, 38(1, Suppl.), 52-58. [Context Link]

 

Tyson A. F., Kendig C. E., Mabedi C., Cairns B. A., Charles A. G. (2015). The effect of incentive spirometry on postoperative pulmonary function following laparotomy: A randomized clinical trial. JAMA Surgery, 150(3), 229-236. [Context Link]

 

Unal A., Tasdemir K., Oymak S., Duran M., Kocyigit I., Oguz F., Tokgoz B., Sipahioglu M. H., Utas C., Oymak O. (2010). The long-term effects of arteriovenous fistula creation on the development of pulmonary hypertension in hemodialysis patients. Hemodialysis International, 14(4), 398-402. [Context Link]

 

Watanabe F. T., Koch V. H., Juliani R. C., Cunha M. T. (2016). Six-minute walk test in children and adolescents with renal diseases: Tolerance, reproducibility and comparison with healthy subjects. Clinics (Sao Paulo), 71(1), 22-27. [Context Link]

 

Webster A. C., Nagler E. V., Morton R. L., Masson P. (2017). Chronic kidney disease. The Lancet, 389(10075), 1238-1252. [Context Link]

 

Y[latin dotless i]lmaz S., Yildirim Y., Yilmaz Z., Kara A. V., Taylan M., Demir M., Coskunsel M., Kadiroglu A. K., Yilmaz M. E. (2016). Pulmonary function in patients with end-stage renal disease: Effects of hemodialysis and fluid overload. Medical Science Monitor, 22, 2779-2784. [Context Link]